Our website uses cookies to improve your on-site experience. By using the website, cookies are being used as described in our Policy Document
Warning: To log in you will need to enable cookies and reload the page (Policy Document)
My ePortfolio Register   
 

Abstract | Full HTML Article | PDF ecancer 10 677 / https://doi.org/10.3332/ecancer.2016.677

Research

VERO® radiotherapy for low burden cancer: 789 patients with 957 lesions

Purpose: The aim of this retrospective study is to evaluate patient profile, feasibility, and acute toxicity of RadioTherapy (RT) delivered by VERO® in the first 20 months of clinical activity.

Methods: Inclusion criteria: 1) adult patients; 2) limited volume cancer (M0 or oligometastatic); 3) small extracranial lesions; 4) treatment between April 2012 and December 2013 and 5) written informed consent. Two techniques were employed: intensity modulated radiotherapy (IMRT) and stereotactic body radiotherapy (SBRT). Toxicity was evaluated using Radiation Therapy Oncology Group/European Organisation for Research and Treatment of Cancer (RTOG/EORTC) criteria.

Results: Between April 2012 and December 2013, 789 consecutive patients (957 lesions) were treated. In 84% of them one lesion was treated and in 16% more than one lesion were treated synchronously/metachronously; first radiotherapy course in 85%, re-irradiation in 13%, and boost in 2% of cases. The treated region included pelvis 46%, thorax 38%, upper abdomen 15%, and neck 1%. Radiotherapy schedules included <5 and >5 fractions in 75% and 25% respectively. All patients completed the planned treatment and an acceptable acute toxicity was observed.

Conclusions: RT delivered by VERO® was administrated predominantly to thoracic and pelvic lesions (lung and urologic tumours) using hypofractionation. It is a feasible approach for limited burden cancer offering short and well accepted treatment with favourable acute toxicity profile. Further investigation including dose escalation and other available VERO® functionalities such as real-time dynamic tumour tracking is warranted in order to fully evaluate this innovative radiotherapy system.

Keywords: hypofractionation, IMRT, low burden cancer, SBRT, VERO®-system

Loading Article Metrics ... Please wait

Related articles

Research: Creating a low-cost virtual reality surgical simulation to increase surgical oncology capacity and capability

Abstract | Full Article | PDF Published: 19 Mar 2019 / https://doi.org/10.3332/ecancer.2019.910

Review: Non-hormonal strategies for managing menopausal symptoms in cancer survivors: an update

Abstract | Full Article | PDF Published: 11 Mar 2019 / https://doi.org/10.3332/ecancer.2019.909

Case Report: Laser thermal ablation to treat a recurrent soft-tissue sarcoma of the leg: a case report

Abstract | Full Article | PDF Published: 05 Mar 2019 / https://doi.org/10.3332/ecancer.2019.908

Review: Petroclival meningiomas: radiological features essential for surgeons

Abstract | Full Article | PDF Published: 05 Mar 2019 / https://doi.org/10.3332/ecancer.2019.907

Research: Younger age and previous exposure to radiation therapy are correlated with the severity of chemotherapy-induced thrombocytopenia

Abstract | Full Article | PDF Published: 26 Feb 2019 / https://doi.org/10.3332/ecancer.2019.906



Founding partners

European Cancer Organisation European Institute of Oncology

Founding Charities

Foundazione Umberto Veronesi Fondazione IEO Swiss Bridge

Published by

ecancer Global Foundation